Catalog

Description

The catalog service allows to register or modify your own sensors/components or query the characteristics of a sensor or provider.

All requests for this service will have the following format:

 http://<your_api_server.com>/catalog/<provider_id>

where provider_id is optional and should be included depending on the operation.

Actions

The available actions for this service are:

Component types

The list of component types should be configured for each Sentilo instance, the following list could be used as a reference for any city:

IdNameDescription
temperatureTemperatureTemperature measurement
noiseSoundmeterSound measurement
windAnemometerWind speed
humidityHumidityHumidity measurement
air_qualityAir QualityAir Quality control
water_qualityWater QualityWater Quality control
meteoMeteorologyWeather Station
parkingOccupation parkingParking control
luminosityLuminosityLuminosity measurement
glass_containerOccupancy container levelGlass occupancy container measurement
paper_containerOccupancy container levelPaper occupancy container measurement
plastic_containerOccupancy container levelPlastic occupancy container measurement
organic_containerOccupancy container levelOrganic occupancy container measurement
refuse_containerOccupancy container levelRefuse occupancy container measurement
container_volumOccupancy container levelGeneric occupancy container measurement
soil_moistureSoil moistureSoil moisture measurement
park_meterParking meterParking meter control
trafficTrafficTraffic measurement
people_flowPeople flowPedestrian flow measurement
flowmeterWater flowWater flow measurement
solenoid_valveElectrovalveSolenoid control
salinitySalinitySoil salinity measurement
internal_ambient_conditionsInternal Environmental ConditionsTemperature, humidity and luminosity measurement
external_ambient_conditionsExternal environmental conditionsTemperature, humidity and luminosity measurement
network_analyzerNetwork analyzerElectric network analyzer
gas_meterGas meterGas consumption meter
electricity_meterElectricity meterElectricity consumption meter
water_meterWater meterWater consumption meter
soil_sensorSoil sensorSoil mesurement of salinity, mosture, etc
genericGeneric component typeDefault component type if not specified
plugsensePlug & SensePlug & Sense Libelium component

Sensor types

The list of sensor types should be configured for each Sentilo instance, the following list could be used as a reference for any city:

IdNameDescription
temperatureTemperatureTemperature measurement
noiseSoundmeter Class IISound level measuring class II.
noise_class_iSoundmeter Class ISound level measuring class I
anemometerAnemometerWind Speed ​measuring
humidityHumidityHumidity measuring
parkingOccupation parkingOccupation parking control
luminosityLuminosityLuminosity measuring
container_volumOccupancy container levelOccupancy container measurement
container_overturnContainer overturnedContainer overturned indicator
container_openContainer openContainer opening indicator
statusSensor status Status control
batteryBattery levelBattery level measurement
soil_moisture_15Soil moisture 15 cm.Soil moisture measurement
soil_moisture_35Soil moisture 35 cm.Soil moisture measurement
park_meterParking meterParking meter control
vehicle_volumeNumber of vehiclesMeasurement of number of vehicles
vehicle_occupation_averageAverage occupancyMeasurement of average occupancy in vehicles
vehicle_speedSpeed ​​VehicleVehicle speed ​​measurement
air_quality_no2NO2Nitrogen dioxide measurement
air_quality_pm10PM10Measurement of suspension particles PM10 
air_quality_pm25PM25Measurement of supsension particles PM25
air_quality_o3O3Ozone measurement
air_quality_so2SO2Sulfur dioxide measurement
air_quality_coCOCarbon Monoxide measurement
air_quality_co2CO2Carbon dioxide measurement
people_flowPeople flowMeasurement of pedestrian flow
flowmeterWater flowWater flow measurement
solenoid_valveElectrovalveSolenoid actuator
etoEvotranspirationEvotranspiration measurement
salinitySalinitySoil salinity measurement
pluviometerPluviometerRain measurement
rainRain gaugeRain indicator (it's raining/it's not raining)
windWind gaugeWind indicator (>X m/s)
wind_direction_6_mWind directionWind direction at 6 meters
wind_direction_10_mWind directionWind direction at 10 meters
voltageVoltmetreElectrical voltage measurement. Units: volts (V)
currentAmmeterElectrical intensity measurement. Units amps (A)
frequencyFrequencymeterElectrical frequency measurement. Units: herzs (Hz)
active_powerActive powerActive power measurement. Units: kilowatts (kW)
reactive_powerReactive powerReactive power measurement. Units: reactive kilovoltiamperis  (kvar)
cosphiPower factorSensor that relates the active and reactive power. No units
active_energyActive electrical energy meterMeasurement of accumulated active power. Units: kWh.
reactive_energyReactive electrical energy meterMeasurement of accumulated reactive power. Units: kvarh.
gas_volumeGas meterMeasurement of accumulated  gas consumption. Units: m3 o Nm3
water_meterWater meterMeasurement of accumulated  water consumption. Units: m3 o l
global_solar_irradianceGlobal solar irradianceMesurement of solar irradiance
leaf_moistureLeaf moistureLeaf wetness
oxygenOxygenO2
vertical_levelVertical levelVertical liquid level (water)
bendBendBend
lpgLpgLiquified petroleum gases (H2, CH4, ethanol & isobutane)
crack_detectionCrack detectionCrack detection gauge
solar_radiationSolar radiationSolar radiation
vocVocVolatile Organic Compounds
chloride_ionChloride ionIon Cl- 
temperatureTemperatureSoil/Water temperature
magnessium_ionMagnessium ionIon Mg2+ 
distanceDistanceDistance (by metalic pressure or by pressure)
conductivityConductivityConductivity
liquid_leakage_lineLiquid leakage lineWater Leakage / Liquid Detection (Line)
crack_propagationCrack propagationCrack propagation gauge
nitrate_ionNitrate ionIon NO3
hall_effectHall effectHall effect
vibrationVibrationVibration (lamina)
copper_ionCopper ionIon Cu2+
calcium_ionCalcium ionIon Ca+
dendometerDendometerTrunk, stem or fruit diameter
iodide_ionIodide ionIon I-
bromide_ionBromide ionIon Br-
sodium_ionSodium ionIon Na+
linear_displacementLinear displacementLinear displacement
atmospheric_pressureAtmospheric pressureAtmospheric pressure
methaneMethaneCH4
pressurePressurePressure/ Weight
ammoniaAmmoniaNH3
redox_potentialRedox potentialOxidation Reduction Potential
proximity_indoorProximity indoorUltrasound (indoor)
air_pollutantAir pollutantAir pollutants-I (NH3, SH2, ethanol and toluene) and air pollutants-II (H2, CH4, CO, ethanol and isobutane)
liquid_leakage_pointLiquid leakage pointWater Leakage / Liquid Detection (Point)
proximity_outdoorProximity outdoorUltrasound (outdoor IP67)
potassium_ionPotassium ionIon K+ 
o_saturationO saturationDissolved Oxygen
presencePresencePresence (PIR)
stretchStretchStretch
liquid_levelLiquid levelHorizontal liquid level (combustibles or water)
loadLoadLoad
fluoride_ionFluoride ionIon F-
phPhpH
solvent_vaporsSolvent vaporsSolvent vapors (H2, CH4, CO, ethanol and isobutane)
accelerometerAccelerometerAccelerometer
Last modified by Administrator on 2017/02/24 18:36